The RFPulse2000A is a wireless data logger that records pulse output signals from various sensors such as flow meters and anemometers. When started, the data logger samples at 100Hz and at the user specified reading rate, recording the total number of pulses from the sample to memory. The RFPulse2000A features an LCD screen which provides instant access to the current reading, minimum, maximum and average statistics. Through the software the device can be programmed to convert the pulse output into a different unit of measure such as gallons per minute or miles per hour. This information can be viewed on the LCD screen of the data logger as well as in the software. The RFPulse2000A is unique in that it not only calculates pulse count, but it also calculates pulse rate. Engineering units can be programmed into the device as a rate, which allows the device to calculate the measurement unit in rates per second, minute, hour or per day. This provides more useful statistics to the user when data logging over long periods of time. The RFPulse2000A can be used as a standalone data logger, or used with the RFC1000 wireless transceiver, to wirelessly transmit data back to a central PC....

Created on: 30 January 2014

MadgeTech’s RFOT is the most advanced wireless temperature data logger in the meat industry today. The RFOT’s rugged design, equipped with a flexible piercing probe allows it to be used in the harshest environments. It is perfectly suited for smoke houses, ovens and other cooking processes up to 212°F (100°C) as well as refrigerators and freezers down to -4°F (-20°C). It is completely splash proof and can withstand wash down cycles. This state-of-the-art device records and transmits internal product temperature readings back to a central computer for instant real-time monitoring. The RFOT never needs to be connected to a computer as it has been designed for two way wireless communication. Full communication can be performed directly from a central PC. In addition to wirelessly transmitting data, the RFOT also stores each reading to internal memory for backup. This backup data may be retrieved wirelessly at a later time. MadgeTech’s easy to use software features user programmable critical control points, called “cooling flags” to assist in compliance with USDA Appendix B. The “cooling flags” are automatically annotated on the graph and tabular data views. The...

Created on: 30 January 2014

The RFCurrent2000A is a wireless data logger with display, designed to measure and record DC current signals. The data logger can connect directly to low-level DC current sources which makes it ideal for (PV) Photovoltaic research to monitor current sourced from solar cells over time, battery usage studies, energy monitoring studies and other DC current monitoring applications. The RFCurrent2000A can also be interfaced with a wide range of current output sensors such as flow meters, pH transmitters and more. Through the software, the device can be programmed with engineering units, which convert the current readings into a different unit of measure such as flow rate. The engineering unit is available for display on the LCD screen as well as in the software. The RFCurrent2000A is available in 20mA, 160mA or a 3A measurement range.   The RFCurrent2000A features an LCD screen which provides instant access to the current reading, minimum, maximum and average statistics. The statistics can be reset through the keypad of the device, allowing customers to keep track of statistics over certain time periods. This feature does not erase the data recorded, but only resets the...

Created on: 30 January 2014

MadgeTechs Vaccine Temperature Monitoring System (VTMS) is ideal for the continuous measurement and data logging of temperature sensitive vaccines or pharmaceuticals in refrigerators, freezers, and coolers. The system includes a NIST traceable RFTCTemp2000A data logger with thermocouple, Glycol bottle and a power supply. Additionally, the RFTCTemp2000A data logger in the VTMS system has a convenient LCD to ensure temperature parameters are met, in real time. The current reading, minimum, maximum and average statistics can all be obtained through the display. In the real-time chart recording mode the VTMS can alert the user, or other personnel, via e-mail or text message if the refrigerator has failed, or if the temperature is outside of the nominal range. This allows users to take immediate actions to ensure vaccines and pharmaceuticals in storage are not destroyed. To prevent false alarms, the RFTCTemp2000A is connected to a Glycol bottle which provides temperature buffered readings.

Created on: 30 January 2014

The Wind101A is a complete system to accurately measure and record wind speed. This low cost wind speed recording system comes complete with the Pulse101A data logger, weatherproof enclosure, a three-cup anemometer and all the necessary cabling to quickly get up-and-running. The Pulse101A data logger can measure and record data for up to 500,000 readings and the storage medium is non-volatile, solid state memory, providing maximum data security even if the battery becomes discharged. The device can be started and stopped directly from a computer using our user-friendly software.

Created on: 30 January 2014

MadgeTech's Ultra Low Temperature Freezer Validation System can measure and log data as low as -86°C. It can be placed in small and large freezers of varying configurations. The system provides a complete stand-alone temperature mapping and validation solution for freezers to ensure uniform storage and testing conditions. The ULT90 includes a USB docking station with 6 feet of cable (IFC300), 9 Cryo-Temp data loggers, and MadgeTech's Secure Software and IQ/OQ/PQ validation protocols, aiding compliance with FDA 21 CFR Part 11. For larger freezers, loggers can be plotted in one graph to show variances in different parts of the freezer. Finally, as failure to monitor external freezer temperatures may invalidate internal freezer temperatures, an additional Cryo-Temp can be included for placement outside of the freezer.

Created on: 30 January 2014

MadgeTech's Ultra Low Temperature Freezer Validation System can measure and log data as low as -86°C. It can be placed in small and large freezers of varying configurations. The system provides a complete stand-alone temperature mapping and validation solution for freezers to ensure uniform storage and testing conditions. The ULT90 includes a USB docking station with 6 feet of cable (IFC300), 15 Cryo-Temp data loggers, and MadgeTech's Secure Software and IQ/OQ/PQ validation protocols, aiding compliance with FDA 21 CFR Part 11. For larger freezers, loggers can be plotted in one graph to show variances in different parts of the freezer. Finally, as failure to monitor external freezer temperatures may invalidate internal freezer temperatures, an additional Cryo-Temp can be included for placement outside of the freezer.

Created on: 30 January 2014

The ThermoVault140 is an extreme high temperature data logging system, for use with a HiTemp140 data logger and stainless steel thermal barrier enclosure. This durable system can withstand temperatures up to 250°C when completely submerged and 350°C in dry heat applications (O-ring removed). The ThermoVault140 is built for use in harsh applications that require extreme temperature monitoring, such as with furnace profiling, geothermal down-hole recording, and oven data logging. The ThermoVault140 is available in multiple probe sizes. The 5.25” probe is ideal for ambient temperature monitoring, while the 24” flexible probe can be easily adjusted to measure hard-to-reach locations, or even the internal temperature of a product.